16. System
16.1. General settings
Click “System Settings” on the left menu bar, and then click “General Settings” on the secondary menu bar to enter the general settings interface. General settings can update the robot system time according to the current computer time so that the time of the log content can be recorded accurately.
Figure 15.1‑1 Time Settings
Network settings can set the controller IP, subnet mask, default gateway, DNS server and teach pendant IP (this IP is valid when using our FR-HMI teach pendant, and the teach pendant enable status needs to be configured to enable when using the FR-HMI teach pendant), which is convenient for customers to use the scene.
16.1.1. Network settings
Figure 15.1‑2 Network settings diagram
Set network card: Enter the network card IP, subnet mask (linked with IP, automatically filled in), default gateway, and DNS server that need to communicate. The factory default IP of network card 0 network port is: 192.168.57.2, and the factory default IP of network card 1 network port is: 192.168.58.2.
Teach pendant enable: Control whether to enable the teach pendant. The teach pendant is turned off by default, and the device cannot be operated using the teach pendant. Click the slide switch button to enable the teach pendant to operate the device.
Access IP: Select the network card associated with WebAPP and WebRecovery. When the teach pendant is enabled, WebAPP selects network card 1 by default, and network card 0 is not selectable.
Set up network: Click the “Set up network” button, and it will prompt that the configuration is in progress. After the configuration is complete, you need to restart the device.
16.1.1.1. No-Login Operation
16.1.1.1.1. Functional Overview
After enabling the No-Login Operation feature on the physical teach pendant, the following functions can be achieved:
When no user is logged into the teach interface, rotating the physical key switch allows the robot to switch between manual/automatic modes, with the end-effector light color changing accordingly.
When no user is logged into the teach interface, in automatic mode, pressing the physical start switch allows the robot to begin running the currently loaded program.
When no user is logged into the teach interface, in automatic mode, pressing the physical stop switch allows the robot to stop running.
16.1.1.1.2. Instructions for Use
Log in to the webapp page, click “System Settings,” then click “General Settings.” In the Teach Pendant section under the Network module, turn on the “Teach Pendant Enable” switch and the “No-Login Operation” switch. Once the feature is enabled, you can control the robot’s manual/automatic mode switching and program start/stop using the physical buttons without being logged into the teach pendant page. This configuration is retained after a power restart.
Figure 15.1‑2-1 Enabling the No-Login Operation Function
16.1.2. Teach pendant touch screen calibration
After enabling the teach pendant, you can calibrate the teach pendant.
Figure 15.1‑3 Teach pendant touch screen calibration
16.1.3. Peripheral industrial computer configuration
To enable the peripheral industrial computer, you need to enter the IP address. After successful configuration, you need to restart the control box and industrial computer.
Figure 15.1‑4 Peripheral IPC Configuration
16.1.4. System Language
16.1.4.1. Language Import
Select a language pack to import (Note: the import file format is [language code].json). If the import is successful and the language pack is not an existing language in the system, a new imported language pack data will be added to the system language.
Figure 15.1‑5 System language interface
16.1.4.2. Language Export
Select the system language, taking English as an example, click the “Export” button, and the exported download file will pop up on the page.
Figure 15.1‑6 Export system language
16.1.4.3. Language Application
Select the system language and click the “Apply” button to switch the system language. After the language is applied successfully, the system will automatically log out to the login page, and the system language will be switched to the current language. Take English as an example:
Figure 15.1‑7 Language system successful interface
16.1.4.4. System safe mode recovery
When the system needs to upgrade or downgrade the version, or the system language pack import fails and the system cannot be entered normally, you need to enter the “System Security Mode Recovery” interface. The specific operations are as follows: 1. Enter the System Settings -> General Settings -> Network Settings interface, adjust the WebRecovery access IP to the network card 0 position, and click “Set Network”.
Figure 15.1‑8 WebRecovery set up the network card interface
After the network settings are successful, restart the control box, switch the IP address to 192.168.57.xxx, and connect the network cable to the control box network card 0.
Log in to the URL “192.168.57.2:8050” and enter the “System Security Mode Recovery” interface.
Figure 15.1‑9 System security mode recovery interface
Software upgrade package import: system software package upgrade or downgrade;
Restore factory language: clear the imported application language package data, restore the factory language package data, and set the default language to English;
16.1.5. Fault data
Click the “Fault Data Save Enable” button to generate a fault data file when the controller fails, saving data 15 seconds before and after the fault.
After saving, you can select all data sources to export in the system settings, and unzip error_data.tar.gz to view the fault data file.
Figure 15.1‑10 Fault data
16.1.6. Timeout Logout Time Setting
Users can set the timeout logout time. If the time is met, the robot will automatically log out. The unit is min.
Figure 15.1‑11 Timeout Logout Time Setting
16.1.7. System Settings
Restoring to factory settings under system recovery can clear user data and restore the robot to factory configuration.
The slave log generation and controller log export functions are to download some important status or error record files of the controller, which is convenient for troubleshooting robot problems.
Figure 15.1‑12 System Settings
16.2. Account settings account settings
Click Account Settings on the secondary menu bar to enter the Account Settings interface. Account management functions are only available to administrators. The function is divided into the following three modules:
16.2.1. User Management
User management page, used to save user information, you can add user ID, function, etc. The user can log in by entering the existing user name and password in the user list.
Figure 15.2-1 User Management
Add users:Click the “Add” button, enter the job number, name, password and select the function.
Important
The job number can be up to 10-digit integer, and the job number and password are uniquely checked, and the password is displayed in Braille. After the user is added successfully, you can enter the name and password to log in again.
Figure 15.2-2 Add users
Edit users:When there is a user list, click the “Edit” button on the right, the job number and name cannot be modified, but the password and function can be modified, and the password also needs to be uniquely verified.
Figure 15.2-3 Edit users
Delete users:The deletion methods are divided into single deletion and batch deletion.
Click the single “Delete” button on the right side of the list, and it will prompt “Please click the delete button again to confirm deletion”, and click the list again to delete successfully.
Click the check box on the left, select the users to be deleted, and then click the batch “Delete” button at the top of the list twice to delete.
Important
The initial user 111 and the current login user cannot be deleted.
Figure 15.2-4 Delete users
16.2.3. Import/Export
Figure 15.2-10 Account settings import/export
Import: Click the “Import” button to import user management and rights management data in batches.
Export: Click the “Export” button to export the data of user management and rights management in batches.
16.3. About
Click About on the secondary menu bar to enter the About interface. This page shows the model and serial number of the robot, the web version and control box version used by the robot, hardware version and firmware version.
Figure 15.3-1 About Schematics
16.3.1. Software Upgrade
16.3.1.1. Operation Preparation
Before upgrading, check and confirm the current software version in “System Settings - About”.
Software upgrade package: Download from the corresponding version’s FARRDOC “Resources Download - Robot Software Download”. After extraction, it contains the software upgrade package “software.tar.gz” for the corresponding version.
16.3.1.2. Important Notes
Data Backup: It is recommended to perform a backup before upgrading (refer to section 3.2.1) to avoid data loss due to upgrade anomalies.
Version Restrictions:
Table 15.3-1 Version Upgrade Restrictions
Current Version |
Maximum Upgradeable Version |
< v3.6.1 |
v3.6.1 |
v3.6.1 - v3.6.4 |
v3.6.5 |
v3.6.5 - v3.6.8 |
v3.6.9 |
v3.6.9 - v3.7.4 |
v3.7.5 |
v3.7.5 |
v3.7.6 |
≥ v3.7.6 |
No restrictions |
Cache Clearance: After each upgrade (especially for cross-version upgrades), it is recommended to clear the browser cache to ensure normal system operation.
16.3.1.2.1. Operation Steps
Software Upgrade:
Under the “System Settings” -> “About” menu, click the “Upgrade” button to enter the software upgrade interface;
Figure 15.3-2 System Upgrade Interface
Click “Choose File” and select the software package “software.tar.gz” downloaded from the official website;
Important
The software upgrade package name must be exactly “software.tar.gz”. If the upgrade package name differs, the upgrade will fail. Rename it to the correct package name.
Click “Upload Upgrade Package” to start the upgrade. The progress bar will be displayed during the upgrade process;
When the upgrade progress reaches 100%, the interface will prompt “Upgrade successful, please restart the control box”;
Figure 15.3-3 Software Upgrade Successful
After restarting the control box, the upgrade is complete. Confirm the version information in “About”.
Firmware Upgrade: After the robot enters BOOT mode, upload the upgrade compressed package, select the required slave stations (control box slave station, body drive slave stations 1~6, end effector slave station) to perform the upgrade operation, and display the upgrade status.
Figure 15.3-4 Firmware Upgrade
Slave Station Configuration File Upgrade: After the robot is disabled, upload the upgrade file, select the required slave stations (control box slave station, body drive slave stations 1~6, end effector slave station) to perform the upgrade operation, and display the upgrade status.
Figure 15.3-5 Slave Station Configuration File Upgrade
Encoder Upgrade: After the robot is disabled, upload the upgrade file, select the required joints (Joint1~Joint6) to upgrade, and configure the encoder mode.
Figure 15.3-6 Encoder Upgrade
16.4. Custom information
Click the custom information of the secondary menu bar to enter the custom information interface. Custom information functions can only be used by administrators. This page can upload user information packages, robot models, and setting teaching program encryption status.
Figure 15.4-1 Custom information schematic diagram
16.4.1. Robot Model
Important
The robot model configured here is a custom robot model name, which is inconsistent with the robot model function configured in “System” -> “Maintenance” -> “Controller Compatible”;
It is not recommended to use names starting with “FR” and “ART”. If you enter a custom robot model starting with “FR” and “ART”, the model name you enter must be consistent with the “Model Abbreviation” in the robot model catalog table (for details of the robot model catalog table, see the “Robot Model Configuration” section).
16.4.2. Parameter range configuration
Parameter range configuration, only the administrator can adjust the parameter range, and the parameters of other authorized members can only be set within the parameter range set by the administrator.
There are two ways to set parameters: slider dragging and manual input.
Important
The maximum value of the parameter range must be greater than the minimum value. 3 seconds after the parameter range is successfully configured, it will automatically jump to the login page, and you need to log in again.
Figure 15.4-2 Schematic diagram of parameter range configuration
16.4.3. Robot License Usage Time
License Usage Time settings
Check the web interface lock screen settings in “Custom” and set whether this function is turned on. When choosing to turn on this function, select the usage period. If not selected, it will prompt “The usage period cannot be empty”.
Note
If the Robot License Usage Time is turned on, secondary settings cannot be made, and the system time cannot be updated.) After selecting the usage period, click the “Configure” button.
After selecting the usage period, click the “Configure” button.
Figure 15.4-3 WEB interface lock screen shutdown settings
Figure 15.4-4 WEB interface lock screen enable settings
Expiration reminder
When the web interface Robot License Usage Time is turned on, the following prompt will appear after logging in to the interface:
1)5 days before the expiration of the device, if you power on and log in successfully, a pop-up window will prompt the remaining days of the use period, which can be eliminated by resetting.
Figure 15.4-5 Boot prompt
2)If the device continues to work, 5 days before the device expires, a pop-up window will automatically pop up at zero o’clock to prompt the remaining days of the service life, which can be eliminated by resetting.
Figure 15.4-6 Continuous work tips
Unlock login
When the web interface Robot License Usage Time is turned on, after the device expires, you will directly enter the lock screen interface when you log in to the webApp for the first time. When the device continues to work, it will automatically log out after obtaining the lock screen data at zero point and enter the lock screen interface. At this time, enter the unlock code to unlock and enter the login interface, enter your login information to log in.
Note
The integrator operates to generate an encrypted unlock code.
Figure 15.4-7 Lock screen
16.5. Robot model configuration
Important
If you need to modify the robot model, please contact our technical engineers and proceed under guidance.
After logging into the collaborative robot console Web, select the corresponding model to modify in the “System Settings” -> “Maintenance Mode” -> “Controller Compatibility” configuration item. For the robot model, refer to the table below.
The robot model table is as follows:
Numerical value |
Model (Main model - Major - Minor) |
Model Abbreviation |
0 |
Not configured |
/ |
1 |
FR3-V1-000(V5.0) |
FR3 V5.0 |
2 |
FR3-V1-001(V6.0) |
FR3 V6.0 |
3 |
FR3-V1-002(V6.0 Mirror) |
FR3 V6.0(Mirror) |
… |
Reserved |
/ |
101 |
FR5-V1-000 |
FR5 V4.0 |
102 |
FR5-V1-001(V5.0) |
FR5 V5.0 |
103 |
FR5-V1-002(V6.0) |
FR5 V6.0 |
… |
Reserved |
/ |
201 |
FR10-V1-000(V5.0) |
FR10 V5.0 |
202 |
FR10-V1-001(V6.0) |
FR10 V6.0 |
… |
Reserved |
/ |
301 |
FR16-V1-000(V5.0) |
FR16 V5.0 |
302 |
FR16-V1-001(V6.0) |
FR16 V6.0 |
… |
Reserved |
/ |
401 |
FR20-V1-000(V5.0) |
FR20 V5.0 |
402 |
FR20-V1-001(V6.0) |
FR20 V6.0 |
… |
Reserved |
/ |
501 |
ART3-V1-000 |
ART3 |
… |
Reserved |
/ |
601 |
ART5-V1-000 |
ART5 |
… |
Reserved |
/ |
702 |
FRCustom(7)-V1-001(FR3-WML) |
FR3-WML |
703 |
FRCustom(7)-V1-001(FR3-WMS) |
FR3-WMS |
… |
Reserved |
/ |
802 |
FRCustom(8)-V1-001(FR5WM) |
FR5WM |
803 |
FRCustom(8)-V1-002(FR5-WML) |
FR5-WML |
804 |
FRCustom(8)-V1-003(FR5-C) |
FR5-C |
… |
Reserved |
/ |
901 |
FRCustom(9)-V1-001(FR3MT) |
FR3MT |
902 |
FRCustom(9)-V1-001(FR10YD) |
FR10YD |
904 |
FRCustom(9)-V1-001(FR3-C) |
FR3-C |
905 |
FRCustom(9)-V01-001(FR30L) |
FR30L |
906 |
FRCustom(9)-V01-001(FR3(C)) |
FR3(C) |
907 |
FRCustom(9)-V01-001(ART3-R6-XM) |
ART3-R6-XM |
908 |
FRCustom(9)-V01-001(FC3-R6-B) |
FC3-R6-B |
… |
Reserved |
/ |
1001 |
FR30-V1-001(V6.0) |
FR30 V6.0 |
… |
Reserved |
/ |
Note
Among them, 10 major version numbers (1-10) are reserved, and 10 minor version numbers (1-10) are reserved.